Lamont, S., Lane, B. and Usmani, A., 2005. The Behaviour Of Multi-storey Composite Steel Framed Structures In Response To Compartment Fires. Fire Safety Science 8: 177-188. doi:10.3801/IAFSS.FSS.8-177
Hamins, A., Mcgrattan, K.B., Prasad, K., Maranghides, A. and Mcallister, T., 2005. Experiments And Modeling Of Unprotected Structural Steel Elements Exposed To A Fire. Fire Safety Science 8: 189-200. doi:10.3801/IAFSS.FSS.8-189
Dong, Y. and Li, X., 2005. The Behaviors Of H-section Steel Beam In Fire. Fire Safety Science 8: 201-209. doi:10.3801/IAFSS.FSS.8-201
Hirashima, T. and Uesugi, H., 2005. Load-bearing Capacity Of H-shaped Steel Columns Under Local Buckling At Elevated Temperature. Fire Safety Science 8: 211-222. doi:10.3801/IAFSS.FSS.8-211
Knobloch, M. and Fontana, M., 2005. Load-carrying Behavior Of Unstiffened Elements At Elevated Temperatures In Fire. Fire Safety Science 8: 223-234. doi:10.3801/IAFSS.FSS.8-223
Wang, Y., Goransson, U., Holmstedt, G. and Omrane, A., 2005. A Model For Prediction Of Temperature In Steel Structure Protected By Intumescent Coating, Based On Tests In The Cone Calorimeter. Fire Safety Science 8: 235-246. doi:10.3801/IAFSS.FSS.8-235
Williams, B., Bisby, L., Green, M., Kodur, V.K.R. and Su, J.Z., 2005. An Investigation On Fire Performance Of FRP-strengthened Wc Beams. Fire Safety Science 8: 247-258. doi:10.3801/IAFSS.FSS.8-247
Bernhart, D., Buchanan, A., Dhakal, R. and Moss, P., 2005. Effect Of Top Reinforcing On The Fire Performance Of Continuous Reinforced Concrete Beams. Fire Safety Science 8: 259-270. doi:10.3801/IAFSS.FSS.8-259
Suhaendi, S.L and Horiguchi, T., 2005. Fiber-reinforced High-strength Concrete Under Elevated Temperature - Effect Of Fibers On Residual Properties. Fire Safety Science 8: 271-278. doi:10.3801/IAFSS.FSS.8-271
Frangi, A. and Fontana, M., 2005. Fire Performance Of Timber Structures Under Natural Fire Conditions. Fire Safety Science 8: 279-290. doi:10.3801/IAFSS.FSS.8-279
Takeda, H., 2005. Fire Resistance Of Exterior Walls: Model And Full-scale Test. Fire Safety Science 8: 291-302. doi:10.3801/IAFSS.FSS.8-291
Konig, J., 2005. Structural Fire Design Of Timber Structures According To Eurocode 5. Fire Safety Science 8: 303-313. doi:10.3801/IAFSS.FSS.8-303
Hertz, K., 2005. Assessment Of Performance-based Requirements For Structural Design. Fire Safety Science 8: 315-325. doi:10.3801/IAFSS.FSS.8-315
Wu, C.W., Lin, T.H., Lei, M.Y., Chung, T.H., Huang, C.C. and Chiang, W.T., 2005. Fire Test On A Non-heat-resistant Fireproof Glass With Down-flowing Water Film. Fire Safety Science 8: 327-338. doi:10.3801/IAFSS.FSS.8-327
Sign In | Membership | Purchase a Volume | Author's Site | Contact
Copyright © International Association for Fire Safety Science